Sliptube
John R. Homer, Shreveport, La.
Woodford has everything you need when it comes time to install or repair an outdoor wall faucet, wall or even a yard hydrant. Once you've determined which one of our freeze proof faucets best serves your needs, take a look at our instructional step-by-step video on how to install it. Watco is the Choice of Professionals when looking for high-quality, innovative and useful bath drain products for your upcoming DIY or repair project. Watco produces bathtub drains, stoppers, bath wastes, lavatory drains and drain parts to fit your bath plumbing needs. Wood blocks or expensive stainless steel supports were the standard until MAPA Products introduced the first plastic based adjustable support for light to medium duty gas piping. This cost effective support started a design trend that revolutionized the rooftop support industry.
Sliptube
.
Because of these considerations sliptube old style gage has always carried a somewhat larger channel than is required for reading and determining the contents of the tank, sliptube.
.
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings. Connect these fittings to Schedule 40 plastic pipe— they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance. See inside your line with this clear pipe, which works in a variety of residential and commercial low-pressure plumbing and water supply applications. Connect this pipe to standard-wall plastic pipe fittings for a variety of residential and commercial low-pressure plumbing and water supply applications. Connect these fittings to thick-wall plastic pipe— they have thicker, stronger walls than standard-wall fittings, so they can handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. They can withstand pressures up to psi. Connect to thick-wall plastic pipe fittings for use in heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. Pipe can handle pressures up to psi.
Sliptube
March 20, H. In one aspect, it relates to apparatus for gauging liquefied petroleum gas in transport truck tanks. When filling tanks of transport trucks with liquefied petroleum gas LP-Gas current practice for gauging such tanks is to use a roto-gauge for determination of deliveries to the truck tank. Roto-gauges are often damaged through vibration and shock resulting from travel over roads and highways and thus become inaccurate.
Northey lights
Homer, Shreveport, La. It is used to measure the depth of this outage space which is left in the tank for the accumulation of gases expanded from the liquid fuel. Therefore, valve seat 5 has been arranged as an extension of the gage head 2; and the stop ringl has been'smoothly surfaced on its upper face and provided-with gasket material 2s which will co-act with valve seat 5 to constitute and to close a valve when the rtube is elevated in the housing. The extreme lower end of the head is provided with a ring extension thereof having a smooth finished lower face rI'his extension is adapted to provide a valve seat, the use and operation oi which will presently be described. It is used to measure the depth of this outage space which is left in the tank for the accumulation of gases expanded from the liquid fuel. Another diiculty with the older gages was that no provision was made for automatically determining, measuring and limiting the outage space so that it would not be filled with liquid. This tube head is threaded internally through the entire length of its vertical opening; and the upper part of the opening is made to carry screw valve I8. Because of these considerations the old style gage has always carried a somewhat larger channel than is required for reading and determining the contents of the tank. Woodford Videos Watco Videos. Of course the length of slip-tube I and the length oi' outage tube 2li can be made and measured to accommodate the requirements of the particular fuel with which this gage is to be used. It is to be observed that if the operator inadvertently left open screw valve I3 and allowed the gage to remain in extended position there would not be enough iluid discharged through orifice 29, and eventually to the atmosphere through opening 22, to constitute a danger of any moment. The drawings and the speciflcationset forth a preferred form of this invention; but modifications in structure and arrangement and relation of the parts of this gage may be made without departing from the spirit of this invention and still effect its objects. Outageftube listhreaded on its upperexternal wall and is carried. It continues to be safe even though these parts are broken off while the gage is fully extended.
Diameters available 60, 80, , , , , , , , , , , , , mm.
Therefore, valve seat 5 has been arranged as an extension of the gage head 2; and the stop ringl has been'smoothly surfaced on its upper face and provided-with gasket material 2s which will co-act with valve seat 5 to constitute and to close a valve when the rtube is elevated in the housing. Share Email Print. Through this orifice there will come just suii'icient fluid to allow accurate reading of the gage. The quantity that would be discharged through orice 29 would be noticeable but not dangerous. The lower end ofslip-tube I is threaded externally; and there is screwedthereon the stop ring 25, the upper circular surface of which is smoothly finished to receive and carry gasket 2B. In the drawings the parts and details of the gage structure are referred to by numerals, in which numeral l is a small straight tube, suiciently long to pass through the top of the tank in which it is carried and the fittings thereabove, and extend almost to the bottom of the tank. Perma-Cast is committed to providing customers with reliable quality components designed to meet the exacting standards of swimming pool owners throughout the world. The outside threads II of the topmost extension of the head 2 are designed to carry sealing cap I2, which has alower finished face, Underneath this face and resting on the shoulder I3 of member 2 there is a ring of packing Iii, provided so that when the cap is screwed down fast it seals the head against the possibility of ,any escape to the atmosphere of any fluid as may appear therein, such as might be present if packing IEI were to leak. A further Objectis to provide means for automatically measuring and indicating the outage space desired to be left unfilled with liquid. The upper part of packing nut 8 is turned inwardly to form a rim I5, having therein one or more slots I a, so that dogs I6 carriedby tube head II may be pressed downwardly through these slots and turned slightly to be engaged by the over-hanging rim I5, and thus lock the tube in place so that it cannot slip upwardly through the gage head 2. Start order.
Certainly. All above told the truth. We can communicate on this theme.