Ieee std 485 2010

A not-for-profit organization, ieee std 485 2010, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. Use of this web site signifies your agreement to the terms and conditions. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice.

Restrictions apply. Abstract: Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in float service are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger s are also beyond the scope of this recommended practice.

Ieee std 485 2010

Active, Most Current. Read more… Read less…. Prices subject to change without notice. About Us. Contact Us. Sign In. Standards Store by Accuris. Purchase History. Currency display settings. Manage society memberships. Featured Products. View All Publishers. Quality Management.

Users are cautioned to check to determine that they have the latest edition of any IEEE standard.

A not-for-profit organization, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. Use of this web site signifies your agreement to the terms and conditions. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger s are also beyond the scope of this recommended practice. Scope: Methods for defining the direct current dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float operations are described. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead acid are beyond the scope of this recommended practice.

A not-for-profit organization, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. Use of this web site signifies your agreement to the terms and conditions. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger s are also beyond the scope of this recommended practice. Scope: Methods for defining the direct current dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float operations are described. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead acid are beyond the scope of this recommended practice. The design of the dc system and sizing of the battery charger s are also beyond the scope of this recommended practice.

Ieee std 485 2010

Methods for defining the direct current dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full-float operations are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice.

Class.of.07.s01

Then, plot the initial voltages for the various loads and draw a straight line through the points. Similarly, if the cell performance in amperes per positive plate is not a constant value for all sizes of a given type of cell, the current for each period during the duty cycle should be adjusted by using the appropriate correction factor as provided by the battery manufacturer. During momentary discharges, there is sometimes little difference between initial and final voltage. In addition, it may be desirable to repeat the calculation to take into account any differences in performance per plate within a given series of cells. View All Publishers. IEEE does not warrant or represent the accuracy or completeness of the material contained in its standards, and expressly disclaims all warranties express, implied and statutory not included in this or any other document relating to the standard, including, but not limited to, the warranties of: merchantability; fitness for a particular purpose; non-infringement; and quality, accuracy, effectiveness, currency, or completeness of material. Culture Documents. Figure B. Justin Bisinger. Because a battery is usually composed of a number of identical cells connected in series, the voltage of the battery is the voltage of a cell multiplied by the number of cells in series. D divided by the number of positive plates. Other information about safety practices, changes in technology or technology implementation, or impact by peripheral systems also may be pertinent to safety considerations during implementation of the standard.

Please insert your email, we will inform immediately after publishing this standard include — discount code. Released: English PDF.

Results of a small-scale pilot study incorporating this method are presented. However, if significant motor starting currents are required from the battery at the beginning of the cycle, the battery voltage should be calculated from initial data using an estimate of the inrush current, and then checking that the initial voltage supports that level of current, iterating the level of current and voltage until a satisfactory solution is obtained. The efficiency should be based on rated UPS output. Ben Horowitz. Consult the manufacturer for factors for the specific battery being evaluated. List of Figures. If the average voltage is known for a particular discharge span and end voltage, the average current can be calculated. Revision will provide additional guidance on sizing with respect to various applications, additional information on load types, and address items of impact due to revision of related documents. Table D. Cochrane Database of Systematic Reviews Angioplasty versus stenting for infrapopliteal arterial lesions in chronic limb-threatening ischaemia. Daniela Jimenez Vallejo. If a battery cell had but one positive plate, and over a particular time period was able to deliver Ah, a cell with two positive plates would deliver Ah and so on. The first section analyzed is the first period of the duty cycle.

1 thoughts on “Ieee std 485 2010

Leave a Reply

Your email address will not be published. Required fields are marked *